Universal Pressure Boiler (UP®)

Design features

A once-through boiler for supercritical applications, usually applied to systems with a capacity of 400 MW or larger; the design features a water-cooled dry bottom furnace, superheater, reheater, economizer, and air heater components — designed for variable superheater pressure load cycling and base load operation.

Capacity, steam output

Typically 2,000,000 lb/h (252 kg/s) to more than 10,000,000 lb/h (1260 kg/s)

Operating pressure

Supercritical, usually at 3500 psi (24.1 MPa) throttle pressure with 5% overpressure

Superheater steam temperatures

As required, currently in the 1100F (595C) range

Fuels

Pulverized coal

Universal Pressure Boiler

Primary Air Fan

Air Heater

Improves boiler performance.

Attemperators

Low NOx Burners

B&W has sold low NOx combustion systems for more than 120,000 MW of generating capacity in both new and retrofit boiler applications.

Forced Draft Fan

Economizer

Overfire Air Ports

B&W Roll Wheel Pulverizers

B&W has sold over 1,100 Roll Wheel pulverizers worldwide.

Reheaters

Selective Catalytic Systems

Air quality control systems designed to eliminate or reduce emissions from the flue gas stream.

Superheaters

Flash Tank

Division Valve

Plantas Novas

Evidenciamos aos nossos clientes a capacidade de executar habilmente soluções inovadoras, desde novos equipamentos até projetos de grande porte, complexos e completos de engenharia e construção.

Modernizações/Retroajustes

A modificação, melhoria e manutenção de equipamentos existentes são considerações vitais para a viabilidade e rentabilidade a longo prazo de todas as operações.

Peças/Serviços

Uma ampla rede de centros regionais de serviços, engenheiros de campo e equipes de suporte técnico está disponível para fornecer serviços personalizados e soluções pós-vendas para atender às suas necessidades.