Design features

A once-through boiler for supercritical applications, usually applied to systems with a capacity of 400 MW or larger; the design features a water-cooled dry bottom furnace, superheater, reheater, economizer, and air heater components — designed for variable superheater pressure load cycling and base load operation.

Capacity, steam output

Typically 2,000,000 lb/h (252 kg/s) to more than 10,000,000 lb/h (1260 kg/s)

Operating pressure

Supercritical, usually at 3500 psi (24.1 MPa) throttle pressure with 5% overpressure

Superheater steam temperatures

As required, currently in the 1100F (595C) range

Fuels

Pulverized coal

Universal Pressure Boiler

Primary Air Fan

Air Heater

Improves boiler performance.

Attemperators

Low NOx Burners

B&W has sold low NOx combustion systems for more than 120,000 MW of generating capacity in both new and retrofit boiler applications.

Forced Draft Fan

Economizer

Overfire Air Ports

B&W Roll Wheel Pulverizers

B&W has sold over 1,100 Roll Wheel pulverizers worldwide.

Reheaters

Selective Catalytic Systems

Air quality control systems designed to eliminate or reduce emissions from the flue gas stream.

Superheaters

Flash Tank

Division Valve

المنشآت الجديدة

نبرهن لعملائنا باستمرار على قدرتنا على تقديم الحلول المبتكرة الناجحة لجميع مشكلاتهم، بدءًا من المعدات الجديدة، وانتهاءً بمشروعات البناء والمشروعات الهندسية الشاملة والمعقدة.

الترقيات / التحديثات

يعد تعديل المعدات الحالية وتحسينها وصيانتها من الاعتبارات الضرورية لاستمرار جميع العمليات لفترة طويلة وتحقيق الربحية منها.

قطع الغيار / الخدمات

تتوفر شبكة ضخمة من مراكز الصيانة الإقليمية المنتشرة في مختلف أرجاء العالم ومهندسي الخدمة الميدانية ومسؤولي الدعم الفني لتقديم حلول الخدمات المُخصصة وخدمات ما بعد البيع بما يلبي متطلباتك.