Millmerran Power Station Units 1 and 2

Millmerran Power Partners
Millmerran, Queensland, Australia

Plant Owner
Millmerran Power Partners

Plant Name
Millmerran Power Station
Units 1 and 2

Project Developer
InterGen

EPC Contractor
Bechtel

Location
Millmerran, Queensland, Australia

Contract Order: 1999

Commercial Operation: 2002

Other Equipment Supplied by B&W

Project Facts

  • Supercritical cycle uses less coal and reduces carbon dioxide emissions when compared to a conventional coal-fired power station.
  • Plant uses low sulfur coal mined from the adjacent Commodore coal deposit.
  • Power station uses only 10% of the water typically required by a generating plant of this size.
  • Electricity produced is pooled in Australia’s national grid to meet increased energy demand.

The Millmerran Power Station Units 1 and 2 began commercial operation in 2002 and are supplying much needed power to meet Australia’s growing energy demand.

B&W Scope

  • Two supercritical coal-fired boilers and related equipment
  • Startup and commissioning advisory services

Boiler Specifications

  • Boiler type: Pulverized coal-fired Spiral Wound Universal Pressure (SWUP™)-type supercritical boiler
  • Design fuel: Low sulfur, bituminous coal (high ash)
  • Capacity: 2 X 420 MW net
  • Steam flow: 2,812,000 lb/h (354 kg/s)
  • Superheater outlet pressure: 3596 psig (24.8 MPa)
  • SH/RH outlet temperature: 1054/1105 F (568/596 C)

 